Rubicon2014 Цитата: 6-я строчка сверху
>> bit is equal to 1,
Это? Всё равно не понял.
Давайте в ПМ наверно.
Я то тут личная переписка спеца с чайником получается.... оно надо другим??
Добавлено: И ещё.
Modify Track Defect List (Level 2 'F')
[more]Description:
The Modify Track Defect List command modifies the defect list for the specified
sector(s).
Quick Help:
"ModTrkDfctLst, F[PSctr/LBA],[Action]";
Input Parameters:
0 - Physical Sector or LBA to Modify.
If Parameter 1 is A1, B1, C1, or F1, this value is an LBA.
If parameter 1 is some other value, this parameter is the physical sector number
of the block to be affected. The cylinder and head come from the current address.
Type: Unsigned 32-bit value
Range: 0 to 0xFFFFFFFF
Default: 0
Note: The track and head used are the current track. When working with sectors
that are already alted, it is best to use the LBA mode actions (B1 and C1
below) .
1 - Defect List Action.
Parameter 1 specifies the format action to be taken. The valid choices are:
A - Add Sector to Alternated Sector List
A1 - Add LBA to Alternated Sector List
B - Add Sector to Pending Sector List
B1 - Add LBA to Pending Sector List
C1 - Remove LBA from Alternated Sector List
F1 - Remove LBA from Alternated Sector List ( same as C1 above )
Type: Unsigned 32-bit value
Range: 0 to 0xFFFFFFFF
Default: 0x0C1
Output Data:
If an error occurred, the following information will be displayed.
"DiagError aaaaaaaa "
where
aaaaaaaa is the Diagnostic Error Code
Examples:
Example #1:
To remove LBA 1234 from the alt list:
F3 2>F1234,f1 Revision History:
0001.0000 Initial Revision.
0002.0000 Remove 2>Fx,F; add Fx,F1 to unalt by sector.
0011.0000 Combined the PSG Diagnostic Error Codes (PSGDEC) and the Diagnostic External
Test Service Error Codes (DETSEC) into a single set of Diagnostic Error Codes
(DiagError).[/more]
Т.е. получается что можно LBA????