[more=Test 3B LOG]Begin Test 3B
EP=0, TA=0, HiGain=1, OTRd=0, Early Rd=0, Splash=1, Reload=1, NPML=1, MRBias=1
Bst/Zap=1, SrvoThrsh=1, RunOut=1, MaxECC=1, ECC 2=1, ECC 1=1, ECC 0=1
Data=50, Write=80, ID=FF, DER=001F, RdWrOpts=27FF
Checking for a Scratch that spans > 2760 tracks or has defects with spans > 1500 tracks on 3 consecutive sectors
Test=3b, Feature=1, cumhlth=70cc, curhlth=7084
AbEnd Test 3B[/more]
[more=Test 9D LOG]Begin Test 9D
ASCII logging on
ASCII logging off
ASCII logging on
Fail Log Summary .....
Cum Health = 70CC
Log 3B - Health 5084
Scanning Log 31 .... Health - 0000
Error Summary Head 0
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 13 0 0
1 0 0 0 9 0 0
2 2 0 0 11 0 0
3 0 0 0 5 0 0
4 0 0 0 10 0 0
5 0 0 0 8 0 0
6 0 0 0 13 0 0
7 0 0 0 6 0 0
8 0 0 0 0 0 0
9 0 0 0 10 0 0
A 0 0 0 0 0 0
B 0 0 0 0 0 0
C 0 0 0 3 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 2 0 0 88 0 0
=====================================================================
Scanning Log 32 .... Health - 0000
Error Summary Head 1
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 5 0 0
1 7 0 9 23 0 0
2 5 0 0 7 0 0
3 0 0 0 6 0 0
4 2 0 0 5 0 0
5 0 0 0 7 0 0
6 3 0 0 1 0 0
7 0 0 0 0 0 0
8 0 0 0 5 0 0
9 0 1 0 53 0 0
A 0 0 0 0 0 0
B 1 0 0 1 0 0
C 0 0 0 3 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 18 1 9 116 0 0
=====================================================================
Scanning Log 33 .... Health - 0000
Error Summary Head 2
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 1 0 0 4 0 0
1 10 0 0 9 0 0
2 28 0 0 0 0 0
3 1 0 0 5 0 0
4 4 0 0 11 0 0
5 6 0 0 3 0 0
6 5 0 0 0 0 0
7 3 0 2 4 0 0
8 0 0 0 1 0 0
9 0 0 0 1 0 0
A 1 0 0 1 0 0
B 1 0 0 0 0 0
C 0 0 0 1 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 60 0 2 40 0 0
=====================================================================
Scanning Log 34 .... Health - 0000
Error Summary Head 3
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 2 0 0
1 0 0 0 1 0 0
2 0 0 0 14 0 0
3 0 0 0 5 0 0
4 0 0 0 14 0 0
5 0 0 0 1 0 0
6 0 0 0 4 0 0
7 2 0 0 26 0 0
8 0 0 0 19 0 0
9 0 0 0 4 0 0
A 0 0 0 0 0 0
B 0 0 0 2 0 0
C 0 0 0 0 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 2 0 0 92 0 0
=====================================================================
Scanning Log A5 .... Health - 0000
Error Summary Head 4
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 16 0 0
1 0 0 0 14 0 0
2 5 0 0 3 0 0
3 1 0 0 9 0 0
4 1 0 0 4 0 0
5 1 0 0 5 0 0
6 2 0 0 2 0 0
7 0 0 0 7 0 0
8 0 0 0 6 0 0
9 0 0 0 9 0 0
A 1 0 0 2 0 0
B 4 0 0 3 0 0
C 0 0 0 3 0 0
D 0 0 0 1 0 0
--------------------------------------------------------------------------------------
Total 15 0 0 84 0 0
=====================================================================
Scanning Log A6 ....
=====================================================================
Scanning Log 3A .... Health - 0000
Error Summary Head 0
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 0 0 0
1 0 0 0 0 0 0
2 0 0 0 0 0 0
3 0 0 0 0 0 0
4 0 0 0 0 0 0
5 0 0 0 0 0 0
6 0 0 0 0 0 0
7 0 0 0 0 0 0
8 0 0 0 0 0 0
9 0 0 0 0 0 0
A 0 0 0 0 0 0
B 0 0 0 0 0 0
C 0 0 0 0 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 0 0 0
Error Summary Head 1
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 0 0 0
1 0 0 0 0 0 0
2 0 0 0 0 0 0
3 0 0 0 0 0 0
4 0 0 0 0 0 0
5 0 0 0 0 0 0
6 0 0 0 0 0 0
7 0 0 0 0 0 0
8 0 0 0 0 0 0
9 0 0 0 0 0 0
A 0 0 0 0 0 0
B 0 0 0 0 0 0
C 0 0 0 0 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 0 0 0
Error Summary Head 2
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 0 0 0
1 0 0 0 0 0 0
2 0 0 0 0 0 0
3 0 0 0 0 0 0
4 0 0 0 0 0 0
5 0 0 0 0 0 0
6 0 0 0 0 0 0
7 0 0 0 0 0 0
8 0 0 0 0 0 0
9 0 0 0 0 0 0
A 0 0 0 0 0 0
B 0 0 0 0 0 0
C 0 0 0 0 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 0 0 0
Error Summary Head 3
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 0 0 0
1 0 0 0 0 0 0
2 0 0 0 0 0 0
3 0 0 0 0 0 0
4 0 0 0 0 0 0
5 0 0 0 0 0 0
6 0 0 0 0 0 0
7 0 0 0 0 0 0
8 0 0 0 0 0 0
9 0 0 0 0 0 0
A 0 0 0 0 0 0
B 0 0 0 0 0 0
C 0 0 0 0 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 0 0 0
Error Summary Head 4
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 0 0 0
1 0 0 0 0 0 0
2 0 0 0 0 0 0
3 0 0 0 0 0 0
4 0 0 0 0 0 0
5 0 0 0 0 0 0
6 0 0 0 0 0 0
7 0 0 0 0 0 0
8 0 0 0 1 0 0
9 0 0 0 0 0 0
A 0 0 0 0 0 0
B 0 0 0 0 0 0
C 0 0 0 0 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 1 0 0
=====================================================================
Scanning Log 36 .... Health - 0000
Error Summary Head 0
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 15 0 0
1 0 0 0 26 0 0
2 0 0 0 132 0 0
3 0 0 0 21 0 0
4 0 0 0 74 0 0
5 0 0 0 30 0 0
6 0 0 0 19 0 0
7 0 0 0 12 0 0
8 0 0 0 26 0 0
9 0 0 0 7 0 0
A 0 0 0 16 0 0
B 0 0 0 0 0 0
C 0 0 0 20 0 0
D 0 0 0 11 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 409 0 0
Error Summary Head 1
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 12 0 0
1 0 0 0 46 0 0
2 0 0 0 67 0 0
3 0 0 0 68 0 0
4 0 0 0 9 0 0
5 0 0 0 24 0 0
6 0 0 0 47 0 0
7 0 0 0 2 0 0
8 0 0 0 3 0 0
9 0 0 0 44 0 0
A 0 0 0 8 0 0
B 0 0 0 4 0 0
C 0 0 0 22 0 0
D 0 0 0 1 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 357 0 0
Error Summary Head 2
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 11 0 0
1 0 0 0 36 0 0
2 0 0 0 8 0 0
3 0 0 0 6 0 0
4 0 0 0 15 0 0
5 0 0 0 6 0 0
6 0 0 0 26 0 0
7 0 0 0 0 0 0
8 0 0 0 0 0 0
9 0 0 0 15 0 0
A 0 0 0 14 0 0
B 0 0 0 8 0 0
C 0 0 0 1 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 146 0 0
Error Summary Head 3
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 5 0 0
1 0 0 0 12 0 0
2 0 0 0 23 0 0
3 0 0 0 32 0 0
4 0 0 0 6 0 0
5 0 0 0 14 0 0
6 0 0 0 4 0 0
7 0 0 0 0 0 0
8 0 0 0 541 0 0
9 0 0 0 0 0 0
A 0 0 0 16 0 0
B 0 0 0 6 0 0
C 0 0 0 0 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 659 0 0
Error Summary Head 4
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 18 0 0
1 0 0 0 11 0 0
2 0 0 0 10 0 0
3 0 0 0 16 0 0
4 0 0 0 16 0 0
5 0 0 0 3 0 0
6 0 0 0 12 0 0
7 0 0 0 22 0 0
8 0 0 0 14 0 0
9 0 0 0 35 0 0
A 0 0 0 18 0 0
B 0 0 0 7 0 0
C 0 0 0 9 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 191 0 0
=====================================================================
Scanning Log 37 .... Health - 0000
Error Summary Head 0
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 25 0 0
1 0 0 0 36 0 0
2 0 0 0 166 0 0
3 0 0 0 31 0 0
4 0 0 0 103 0 0
5 0 0 0 38 0 0
6 0 0 0 37 0 0
7 0 0 0 21 0 0
8 0 0 0 47 0 0
9 0 0 0 15 0 0
A 0 0 0 27 0 0
B 0 0 0 0 0 0
C 0 0 0 26 0 0
D 0 0 0 17 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 589 0 0
Error Summary Head 1
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 23 0 0
1 0 0 0 62 0 300
2 0 0 0 83 0 0
3 0 0 0 80 0 0
4 0 0 0 18 0 0
5 0 0 0 33 0 0
6 0 0 0 70 0 0
7 0 0 0 4 0 0
8 0 0 0 8 0 0
9 0 0 0 152 0 90
A 0 0 0 14 0 0
B 0 0 0 6 0 0
C 0 0 0 24 0 0
D 0 0 0 2 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 579 0 390
Error Summary Head 2
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 16 0 0
1 0 0 0 47 0 0
2 0 0 0 11 0 0
3 0 0 0 8 0 0
4 0 0 0 20 0 0
5 0 0 0 8 0 0
6 0 0 0 34 0 0
7 0 0 0 3 0 128
8 0 0 0 4 0 0
9 0 0 0 18 0 0
A 0 0 0 18 0 0
B 0 0 0 9 0 0
C 0 0 0 2 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 198 0 128
Error Summary Head 3
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 10 0 0
1 0 0 0 21 0 0
2 0 0 0 44 0 0
3 0 0 0 41 0 0
4 0 0 0 8 0 0
5 0 0 0 22 0 0
6 0 0 0 5 0 0
7 0 0 0 4 0 0
8 0 0 0 761 0 0
9 0 0 0 3 0 0
A 0 0 0 22 0 0
B 0 0 0 10 0 0
C 0 0 0 0 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 951 0 0
Error Summary Head 4
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 30 0 0
1 0 0 0 15 0 0
2 0 0 0 22 0 0
3 0 0 0 27 0 0
4 0 0 0 21 0 0
5 0 0 0 11 0 0
6 0 0 0 16 0 0
7 0 0 0 34 0 0
8 0 0 0 5 0 0
9 0 0 0 0 0 0
A 0 0 0 0 0 0
B 0 0 0 0 0 0
C 0 0 0 0 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 181 0 0
=====================================================================
Scanning Log 3B .... Health - 5084
Error Summary Head 0
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 0 0 0
1 0 0 0 0 0 0
2 0 0 0 0 0 0
3 0 0 0 0 0 0
4 0 0 0 0 0 0
5 0 0 0 0 0 0
6 0 0 0 0 0 0
7 0 0 0 0 0 0
8 0 0 0 0 0 0
9 0 0 0 0 0 0
A 0 0 0 0 0 0
B 0 0 0 0 0 0
C 0 0 0 0 0 0
D 0 0 0 0 0 0
--------------------------------------------------------------------------------------
Total 0 0 0 0 0 0
Error Summary Head 1
Zone EC13 EC1B EC1C EC43 EC49 EC50
0 0 0 0 0 0 32
1 0 0 0 0 0 215
2 0 0 0 0 0 93
3 0 0 0 0 0 94
4 0 0 0 0 0 26
5 0 0 0 0 0 42
6 0 0 0 0 0 74
7 0 0 0 0 0 4
8 0 0 0 0 0 18
9 0 0 0 0 0 328
A 0 0 0 0 0 14
B 0 0 0 0 0 8
C 0 0 0 0 0 30
D 0 0 0 0 0 2
--------------------------------------------------------------------------------------
Total 0 0 0 0 0 980
=====================================================================
Scanning Log 3C .... No log on disk
=====================================================================
Scanning Log 3D .... No log on disk
=====================================================================
ASCII logging off
Test=9d, Feature=0, cumhlth=70cc, curhlth=7084
AbEnd Test 9D[/more]
В 9D, вроди, много ошибок особенно по 1 и 3 чуть меньше по 0-й.
Full LOG -
http://zalil.ru/33748763